In summer the battery is full by noon and covers the house in the evening. Winter is different: the panels produce only a fraction of the energy, days are short and a battery in an unheated space also has to watch its temperature. Here is what happens to a home battery in winter, how to set the minimum state of charge and reserve, when charging from the grid makes sense and why an occasional full charge is worth it.
Low production: what to expect in winter
In mid-winter a solar system in central Europe produces roughly a quarter to a third of what it does in June – the exact ratio depends on latitude, panel tilt, shading and weather. On overcast days there is often no surplus at all and the battery gets nothing from the sun. On those days its value depends mainly on whether you use it to store cheap grid energy.
What to expect on a given day is shown by a solar production forecast – in winter it matters even more than in summer, because it decides whether to top up the battery from the grid overnight.
Temperature and the BMS: why charging slows down in the cold
Lithium cells – including the LiFePO4 cells common in home batteries – must not be charged at full current at low temperatures. Charging in freezing conditions can permanently damage the cells. That is why the BMS (battery management system) measures cell temperature and limits the allowed charge current accordingly; around or below freezing it may block charging entirely. Discharging is usually allowed down to lower temperatures than charging, but can be limited too.
In practice, the inverter would charge the battery but the battery accepts only a small amount of power – or none. That is not a fault but cell protection.
- Location: a battery in a garage or attic is colder in winter than one in a living space. Some batteries have built-in heating; whether yours does and when it switches on is in the manual.
- Temperature range: the battery manufacturer specifies operating temperatures for charging and discharging in the datasheet. Follow those – they differ between models.
- Watch the temperature: if the battery stops charging for long periods in winter, check the cell temperature reported by the BMS.
Minimum SOC and reserve
The minimum state of charge (SOC) is the level below which the inverter will not discharge the battery. Winter is a good time to reconsider it:
- Protecting the battery: sitting at a very low SOC for long periods is not good for it. When the sun does not recharge the battery for several days, the minimum SOC keeps it in a safe range.
- Backup during outages: if you have backup power wired in, the reserve above the minimum decides how long the house lasts in a grid outage. In winter, when the sun may not recharge the battery, a higher reserve is worth considering.
- The trade-off: the higher the reserve, the less capacity is left for everyday use – every unused kilowatt-hour in reserve has to be bought from the grid.
Recommended minimum SOC values come from the battery manufacturer; change the inverter setting according to its manual or with your installer.
Charging from the grid off-peak or at cheap spot prices
When the sun is not enough, the battery can take on a different role: charge in cheap hours and cover expensive ones. On a time-of-use tariff that means charging off-peak and discharging at peak; on a dynamic (spot) tariff, charging at night or in other cheap intervals and discharging in the evening peak.
- The price difference must cover charge and discharge losses (roughly 10–20 % for home systems) and battery wear.
- In the cold the BMS may limit charge power – at night, when it is coldest, the battery may not fill completely within a few off-peak hours.
- Before a sunny day, leave room in the battery for the surplus.
Detailed calculations with examples are in Time-of-use tariffs with solar and a battery and Dynamic electricity prices and batteries.
An illustrative example
Say a battery with 10 kWh of usable capacity charges off-peak in winter at 0.15 EUR/kWh and covers consumption at peak at 0.30 EUR/kWh (all fees included). With 90 % efficiency and wear of 0.05 EUR/kWh, the saving is about 0.08 EUR per kilowatt-hour, roughly 0.80 EUR a day. The numbers are illustrative – with a small difference between tariffs, grid charging can even lose money.
Time windows on Deye inverters
Deye inverters can control battery charging and discharging by time windows (Time of Use): for each period of the day you set whether the battery may charge from the grid and to which state of charge. The exact procedure depends on the model and firmware version – follow the inverter manual or ask your installer.
SOC calibration
The state of charge shown by the battery is an estimate made by the BMS. If the battery is not fully charged for a long time – typically in winter – the estimate can drift from reality. The battery might show 20 % but shut down earlier, or the other way round. Many batteries recalibrate when they are charged to 100 % from time to time, because a full charge gives the BMS a fixed reference point. Whether and how often your battery needs this is stated by the manufacturer – in winter it can mean topping it up from the grid to full every now and then.
Follow the battery manufacturer's manual: temperature limits, minimum SOC, heating and calibration vary by model. The information in this article is general. If you are unsure about a setting, ask your installer.
How Solarmeter shows your battery in winter
- State of charge, battery power and energy flow in real time – every 60 seconds on the Monitor plan, with history, so you can see when the BMS limited charging.
- The production forecast for today and tomorrow helps you decide whether to charge from the grid overnight.
- Day-ahead spot prices and your peak/off-peak schedule; the savings calculation shows what grid charging actually brought.
- On Deye inverters on the Control plan, Solarmeter builds a battery charging plan from the forecast and spot prices and the local agent writes it to the inverter as a time-of-use schedule – only after you explicitly switch it on; otherwise Solarmeter only reads data.