On a time-of-use tariff you pay a different price for grid electricity at different times of day: more in the peak period, less in the off-peak period. Solar panels and a battery add a third source – your own production, which is "free" during the day. Here is how off-peak tariffs work and how to align consumption, water heating and battery charging with them, using the Czech HDO system as a worked example.
What a time-of-use tariff is
A time-of-use (TOU) tariff splits the day into periods with different prices – typically a cheaper off-peak period at night or around midday and a more expensive peak period in the morning and evening. Many countries have some form of it: night-rate tariffs with a two-register meter, or newer smart-meter tariffs with several bands.
Who sets the hours varies. Sometimes it is your supplier, sometimes the network operator, and with some tariffs the hours differ from one household to another.
Example: HDO in the Czech Republic
In the Czech Republic off-peak periods are driven by HDO (ripple control). The distribution system operator sends a signal over the grid that switches the meter between high tariff (VT) and low tariff (NT). For many tariffs the same signal also switches selected appliances – typically the hot-water cylinder or storage heaters – which may then run only in the low tariff.
Low-tariff hours are not the same everywhere. The operator sets them by the HDO code of your connection point, and the low tariff is often split into several blocks across the day and night. The current schedule is published by your operator (ČEZ Distribuce, EG.D or PREdistribuce) by HDO code.
Czech distribution tariffs at a glance
How long the low tariff lasts depends on the distribution tariff. Eligibility for a longer low tariff is usually tied to how the home is heated or how water is heated, and the operator may impose technical conditions such as appliance blocking. For orientation:
| Tariff | Low tariff | Typical use |
|---|---|---|
| D02d | none (single rate) | an ordinary household without electric heating |
| D25d | 8 hours a day | storage water heating (hot-water cylinder) |
| D45d | 20 hours a day | direct electric heating |
| D56d | 22 hours a day | heat pump heating |
The overview is simplified – there are more tariffs and conditions can change. Outside the Czech Republic the names and hours are different, but the logic of a cheap and an expensive period is the same.
What exactly is cheaper off-peak
Your price consists of the energy part (from your supplier) and a regulated network part. On a two-rate tariff both usually differ, and the network difference is often significant. On a dynamic (spot) tariff the energy price changes every 15 minutes and the peak/off-peak network charge comes on top – see Dynamic electricity prices and home batteries.
The order in which to use energy
With solar and a battery, a simple order works well:
- Own production straight into consumption. The cheapest kilowatt-hour is the one you produce and use right away – no battery losses, no fees.
- Surplus into the battery. Stored energy replaces evening purchases at the peak rate.
- Off-peak grid energy for what the sun and battery cannot cover – mainly in winter and on overcast days.
- Peak-rate grid energy only when none of the above is enough.
Exporting surplus comes last – the feed-in price is usually much lower than the purchase price, because you do not get network charges or taxes back on exported energy.
Water heating: sun or off-peak?
A hot-water cylinder is the largest shiftable load in most homes, and with solar it becomes a "thermal battery". Without changes, however, ripple control lets it run only in the low tariff – which often falls at night, when the panels produce nothing.
- In summer heating water from the daytime surplus is usually enough. Surplus diverters send only unused production to the heating element.
- In winter production falls short and the off-peak period remains an important backup.
- Mind the tariff conditions. On some tariffs blocking the appliance by the HDO signal is a condition. Change the wiring of the cylinder or the ripple-control receiver only with an electrician and in line with your network operator's rules.
Charging the battery off-peak
Charging the battery from the grid off-peak makes sense when energy stored now replaces a more expensive peak purchase later – and when the room does not need to stay free for the sun. Two things decide:
- The peak/off-peak price gap must cover charge/discharge losses (roughly 10–15 % for home systems) and battery wear.
- Tomorrow's production forecast. If it will be sunny, overnight charging takes up room for the midday surplus. That is why a solar production forecast belongs in the decision.
An illustrative example
Say a kilowatt-hour costs 0.16 EUR off-peak and 0.24 EUR peak, all fees included, cycle efficiency is 90 % and wear is estimated at 0.04 EUR/kWh. Saving per kilowatt-hour: 0.24 − 0.16 ÷ 0.9 − 0.04 ≈ 0.02 EUR. The gap is small – grid charging off-peak pays off here only on days when the battery would otherwise stay empty. With a smaller gap it turns negative. The numbers are illustrative; real prices depend on your tariff, network operator and supplier.
Long off-peak periods
With a tariff such as D45d or D56d the low tariff covers most of the day and the high tariff only a few short blocks. The battery is then best used to cover those blocks and to store your own production – arbitrage between peak and off-peak brings little.
How Solarmeter shows tariffs
- You enter your time-of-use schedule (HDO) and prices for peak and off-peak; Solarmeter then knows which hours are cheap.
- Savings account for peak/off-peak rates and the feed-in price – fixed, or spot minus a fee.
- OTE day-ahead spot prices for today and tomorrow in 15-minute steps, if you are on a spot tariff.
- A production forecast for today and tomorrow helps you decide whether to charge overnight.
On Deye inverters, the local agent on the Control plan can write a time-based battery charging and discharging schedule (Time of Use) to the inverter, so charging can follow your off-peak hours – only ever after you explicitly switch it on. Automatic planning from the production forecast and spot prices is in preparation. Plan details are on the pricing page, supported models on Supported inverters.
Work it out on your own data: enter your off-peak schedule and peak and off-peak prices and Solarmeter shows how much your solar system and battery really save.