Three-phase hybrid inverters with a low-voltage (LV) battery
- Series and models
SUN-xK-SG04LP3 SUN-xK-SG05LP3
- Connection
- Solarman data logger (Wi-Fi/LAN) – local agent
- Deye Cloud – nothing to install
- Enable Modbus
- no – The Solarman data logger talks to the inverter on its own, nothing needs to be enabled.
- Monitoring
- Supported Local agent (data every 10 s) and Deye Cloud (roughly every 5 minutes).
- Charge control
- Beta Time-of-use battery charging and discharging via the local agent – verified on a real inverter.
OEM variants of the same series (e.g. Sunsynk, Sol-Ark, Turbo Energy, Afore) are built on the same platform and Solarman data logger. We have verified the Deye SUN-15K-SG05LP3 on hardware – for an OEM variant, send us the model before connecting.
Hybrid inverters – three-phase HYD-KTL-3PH and HYD-EP, older HYD-ES and ME3000SP
- Series and models
HYD 5…20KTL-3PH HYD-EP HYD-ES ME3000SP
- Connection
- Solarman data logger (Wi-Fi/LAN) – local agent
- RS485 converter (Modbus RTU)
- Enable Modbus
- no – Nothing to enable with a Solarman data logger (LSW-3 / LSE-3). Alternatively an RS485 converter directly on the inverter.
- Monitoring
- Beta Beta – the same Solarman data logger as Deye. Being verified with our first customers.
- Charge control
- Coming soon Coming soon.
The older HYD-ES and ME3000SP series use a different register map – we verify it with you when connecting.
Hybrid inverters ET / ET Plus+, EH, BT / BH
- Series and models
ET / ET Plus+ EH BT / BH
- Connection
- Manufacturer Wi-Fi/LAN dongle (Modbus TCP)
- RS485 converter (Modbus RTU)
- Enable Modbus
- yes – Modbus TCP must be enabled in the SolarGo app (LAN+Wi-Fi 2.0 dongle or Kit-20), sometimes only via GoodWe service. Alternatively an RS485 converter on the EMS port.
- Monitoring
- Coming soon Coming soon – we are looking for our first customers.
- Charge control
- Coming soon Coming soon.
Older Wi-Fi kits without Modbus TCP are not supported yet.
Hybrid inverters X1-Hybrid G4 (1-phase) and X3-Hybrid G4 (3-phase)
- Series and models
X1-Hybrid G4 X3-Hybrid G4
- Connection
- Manufacturer Wi-Fi/LAN dongle (Modbus TCP)
- RS485 converter (Modbus RTU)
- Enable Modbus
- yes – Modbus TCP via Pocket WiFi 3.0 or WiFi+LAN requires current dongle and inverter firmware (updated by SolaX service). An RS485 converter on the COM port is the most reliable option.
- Monitoring
- Coming soon Coming soon – we are looking for our first customers.
- Charge control
- Coming soon Coming soon.
The older Pocket WiFi 2.0 and PocketLAN do not provide Modbus.
SUN2000 L1 (1-phase) / M1 (3-phase) inverters with a LUNA2000 battery and DTSU666-H meter
- Series and models
SUN2000 L1 / M1 LUNA2000 DTSU666-H
- Connection
- Huawei SDongleA-05 (Modbus TCP)
- RS485 converter (Modbus RTU)
- Enable Modbus
- yes – Modbus TCP must be enabled in the FusionSolar app (dongle settings, Modbus-TCP), usually with an installer account.
- Monitoring
- Coming soon Coming soon – we are looking for our first customers.
- Charge control
- Coming soon Coming soon.
The dongle allows only one connection – it must not be used by another integration such as Home Assistant at the same time.