Solarmeter

How to read solar PV data: production, consumption, export, battery and strings

A monitoring dashboard shows dozens of numbers. On most days only a handful matter – as long as you know what a normal day looks like, so you notice when something is off.

Published

A solar PV system with a battery is a small energy system with four flows: production from the panels, household consumption, the grid (import and export) and the battery (charge and discharge). At every moment the balance has to hold: whatever is produced, imported and discharged is consumed, exported or stored (minus small inverter losses). Keep that equation in mind and most monitoring charts start to make sense.

Production: the shape of the curve tells you more than the number

On a clear day production forms a smooth bell: it rises in the morning, peaks around solar noon (for south-facing panels) and falls towards the evening. East-west arrays give a flatter, wider curve or two humps. Clouds show up as irregular spikes and dips.

What to look for

  • A flat-topped peak. If production sits at one value for a long time around noon, it hit a limit – either the inverter's rated power (clipping) or a configured export limit while the battery is full and the house uses little. Occasionally that is fine; every sunny summer day is worth a look at the settings.
  • Production versus forecast. "18 kWh today" means nothing until you know what to expect. Solarmeter computes a production forecast from the weather and the tilt, azimuth and size of each string – a large, repeated gap on clear days is a signal. How the forecast is made and how accurate it is: Solar production forecast.
  • Month versus a typical year. One cloudy week proves nothing. Monthly production compared with the typical year from PVGIS (the European Commission's solar database) shows whether the plant delivers what it should in the long run.

Consumption: watch the night-time baseline

Household load varies the most and on its own rarely points to a fault. What is useful is the night-time baseline – the load the house draws when nobody is doing anything (fridge, router, circulation pumps, standby electronics and the inverter's own consumption). If that value rises permanently from one week to the next, something new is staying on: a faulty thermostat, a heating cable, a forgotten heater in the garage.

The second useful figure is the self-consumption share – how much of your production is used at home (directly or via the battery) and how much goes to the grid. In most markets a self-consumed kilowatt-hour is worth more than an exported one, because it also saves network charges and taxes.

Grid: import, export and feed-in limits

The grid figure has two directions. Import is energy you buy, export (feed-in) is energy you send out. A typical day with a battery looks roughly like this: import in the morning, battery charging before noon, export in the afternoon, battery discharging in the evening and at night, and only then import again.

Signals worth attention

  • Grid import in the middle of a sunny day with low load and a battery that is not full – check whether the inverter is set to charge from the grid at the wrong time, or reports an error.
  • Zero export despite sun and a full battery – this may be a deliberate zero-export setting (for example if your grid connection does not allow feed-in); otherwise you are giving up export income.
  • Export above what your grid operator approved – the export limit in the inverter should match your connection agreement.

Battery: state of charge is not enough

For batteries most people watch the state of charge (SOC) in percent. To judge the battery's condition, charge and discharge power, voltage and temperature matter just as much.

  • The battery does not reach full on a sunny day. Either the surplus is small (high daytime load), the charge current is limited, or the battery only charges up to a configured maximum.
  • SOC jumps of tens of percent within minutes usually mean the battery management system (BMS) recalculated its state. Once in a while that happens; regularly, it points to a calibration or cell issue.
  • The battery discharges to the grid or charges from it when you did not intend it to – check the time-of-use schedules in the inverter.
  • High temperature in summer or very low temperature in winter limits charging power. A battery in an unheated garage charges much more slowly in frost – not a fault, just cell chemistry.

Strings: the most sensitive fault indicator

A string is a series of panels connected to one inverter input. Comparing strings is the most reliable way to catch a faulty panel, a loose connector or new shading – the weather affects all strings alike, so the difference between them filters the weather out.

How to compare strings

  • Strings with the same orientation and panel count should deliver almost the same power. A persistent gap of more than a few percent deserves an inspection.
  • Lower voltage on a string with similar current often means one or more panels in the series are bypassed (failed bypass diode, damaged cell).
  • Lower current at similar voltage points rather to shading, soiling or degradation.
  • A drop only at a certain hour is typically shade – a grown tree, a new chimney, a neighbouring building.

Solarmeter computes a daily performance ratio (PR) for every string – actual production divided by the production expected from satellite irradiance measurements. When a string keeps lagging behind the others or output suddenly drops, it alerts you before you notice on your bill.

Cheat sheet: signal, likely cause, what to do

What you seeLikely causeWhat to do
One string permanently below the othersfaulty panel, connector, shade, dirtcompare voltage and current, inspect the panels
Flat production peak every sunny dayinverter clipping or export limitcheck limit settings and inverter sizing
Clear-sky production well below forecastfault, snow, wrong string parameterscheck string settings and inverter status
Permanently higher night-time loadnew or faulty appliancego through devices running at night
Unexpected charging from the gridinverter time schedulereview the time-of-use settings
No data arrivinginternet, logger or cloud outagecheck the logger connection and data freshness

A simple routine that is enough

  • Daily (a few seconds): is data arriving and is the plant producing roughly as forecast?
  • Weekly: are the strings balanced and does the battery charge as expected?
  • Monthly: production against the typical year, night-time load and your savings.

On a dynamic tariff, also look at when the battery charges and discharges – see Dynamic electricity prices and home batteries. If you are still choosing how to connect your inverter, start with Monitoring a Deye inverter.

Solarmeter shows production, consumption, grid, battery and individual strings on one screen and flags what looks wrong. For Deye via Deye Cloud it is free.

Try it free

All guides →

Keep your solar plant under control

Signing up takes a minute. For Deye via Deye Cloud, Solarmeter is free forever.