Solarmeter

Dynamic electricity prices and home batteries: when to charge, when to export, how to count savings

On a dynamic (spot) tariff the price of electricity changes every hour or even every 15 minutes. A battery can then earn money beyond sunny days – provided you count every fee and every loss.

Published

On a dynamic electricity tariff you do not pay one fixed price per kilowatt-hour – you pay a price that follows the wholesale market through the day. For owners of a solar PV system with a battery that opens new options: charge the battery cheaply from the grid when the sun will not be enough, and save stored energy for the expensive evening hours. To make it pay off, though, you have to work with the full retail price, not just the wholesale number.

What a day-ahead spot price is

Across most of Europe, wholesale electricity is traded on coupled day-ahead markets (run by exchanges and market operators such as EPEX SPOT, Nord Pool or OTE in the Czech Republic). Prices for the next day are published the day before, typically shortly after noon, so you always know what tomorrow looks like. Since October 2025 the European day-ahead market works in 15-minute intervals, so the price can change several times within an hour.

Prices are quoted in EUR/MWh. For a household it is easier to think in kWh: 100 EUR/MWh is 0.10 EUR/kWh – before any fees, network charges or taxes.

A typical day

  • Night: lower prices, low demand.
  • Morning: a first peak as homes and businesses start up.
  • Midday: often very cheap in summer, even negative when solar output is high.
  • Evening: the most expensive part of the day – the sun sets while demand is high.

The spot price is not your price

This matters for every calculation: for a kilowatt-hour from the grid you pay the spot price plus your supplier's margin, a regulated network (distribution) charge, other levies and VAT. Network charges and levies are usually the same for every hour, or differ only between peak and off-peak periods of your network tariff.

Many countries have time-of-use network tariffs. In the Czech Republic, for example, the grid operator switches meters between high and low tariff by a ripple-control signal (HDO) at set hours. The difference between peak and off-peak network charges can matter as much as the difference in the spot price. How to align consumption, water heating and a battery with off-peak hours is covered in Time-of-use tariffs with solar and a battery.

Export works differently: on a spot-indexed feed-in contract you typically receive the spot price minus a fee. You do not get the network charges or taxes back on exported energy. That is why a self-consumed kilowatt-hour is almost always worth more than a sold one.

When charging the battery from the grid pays off

Grid charging makes sense when energy stored now replaces a more expensive purchase later – and still covers losses and wear:

saving per kWh = price you avoid later − price you pay now ÷ efficiency − battery wear

  • Efficiency of a full charge-discharge cycle (through inverter and battery) is roughly 85–90 % for common home systems. From 1 kWh bought, you get less back in the evening.
  • Wear = battery price divided by the energy it will cycle over its life (capacity × warranted cycles). Every extra cycle uses up some lifetime.

An illustrative example

Say a kilowatt-hour costs 0.15 EUR at night (off-peak network charge, cheap spot) and 0.35 EUR in the evening peak, all fees included. Efficiency is 90 %, wear is estimated at 0.05 EUR/kWh:

0.35 − 0.15 ÷ 0.9 − 0.05 ≈ 0.13 EUR saved per kilowatt-hour. At 8 kWh a day that is about 1 EUR per day. If the night-to-evening difference is only 0.10 EUR, the result turns negative – grid charging does not pay.

The numbers are illustrative; your actual prices depend on your supplier, network tariff and country.

When not to charge from the grid

If tomorrow's forecast promises sun, leave room in the battery. Filling it from the grid overnight means the midday surplus has nowhere to go and is exported at a low or even negative price. That is why a production forecast matters as much as prices – more in Solar production forecast.

When to export and when to keep the energy

Solar surplus

Once the battery is full, surplus goes to the grid anyway. The choice is only the order: in summer it can pay to export in the morning (while prices still hold) and top up the battery around noon, when spot prices are lowest. That only works if the forecast reliably shows there will be enough sun left to fill it.

Discharging the battery to the grid

Selling battery energy to the grid only pays in pronounced price spikes: the export price (spot minus fee) must exceed what you would pay to buy the same energy back later, and also cover losses and wear. For most households discharging into their own evening consumption is the better deal.

Negative prices

When prices are negative, exporting costs you money. In those intervals it is better to limit export, charge the battery and shift loads into that window – water heating, the washing machine or EV charging.

How to calculate real savings

Your savings are the difference between what you would pay without the plant and what you pay with it. On a dynamic tariff this has to be computed interval by interval, not from daily totals:

  • self-consumption (direct and from the battery) × import price in that interval,
  • + export × feed-in price in that interval,
  • − grid energy bought to charge the battery × import price in that interval.

A kilowatt-hour saved at 7 pm is worth something different from one at 1 pm. Using a monthly average price usually underestimates what the battery saves and overestimates the value of export.

How Solarmeter shows it

  • Day-ahead spot prices for today and tomorrow in 15-minute intervals – currently from OTE, the Czech market operator.
  • Peak and off-peak tariffs from your time-of-use schedule, and export at a fixed price or spot minus a fee.
  • Savings per day, month and year – self-consumption, import, export and battery in one overview.
  • A production forecast for today and tomorrow based on the weather and your string parameters.

On Deye inverters the local agent can set time-based battery charging and discharging (Time of Use). Automatic charge planning from the production forecast and spot prices is in preparation – and will only ever run once you explicitly turn it on. See supported inverters for which models support it.

If you first want to understand what the numbers in your monitoring mean, read How to read your solar PV data.

Try it on your own data: enter your tariff schedule and prices, and Solarmeter calculates what your plant and battery actually save.

Try it free

All guides →

Keep your solar plant under control

Signing up takes a minute. For Deye via Deye Cloud, Solarmeter is free forever.